Current Perspective on Fiberglass Posts Length: Finite Element Study

Authors

DOI:

https://doi.org/10.15517/ijds.2024.61452

Keywords:

Finite element analysis; Maxillary central incisor; Endodontically treated teeth; Fiberglass post; Post length; Fracture resistance.

Abstract

The literature to date has not reported a clear consensus on the optimal length of fiberglass posts for efficient clinical performance when restoring endodontically treated maxillary incisors with severe crown destruction. This study aimed to determine the stress distribution of fiberglass posts at different lengths using finite element analysis. Five 3D finite element models (groups A-E) were created, each representing a restoration system for endodontically treated maxillary central incisors. The models included post-core crowns with crown-root ratios of 1/3, 1/2, 2/3, 4/5, and 1/1. A static load of 100N force was applied to the palatal surface at 45º to the long axis of the tooth. Von Mises values and | maximum stresses in the crown, dentin, resin cement, and post-core were evaluated separately. The maximum stress experienced was A < C < B < E < D. Von Mises stresses were located in the upper and middle buccal thirds and in the apical palatal third of post A, as well as the upper and middle buccal thirds in posts B, C, D, and E. The lowest distribution of maximum and Von Mises stresses was observed in model A.

Downloads

Download data is not yet available.

References

Cruzado-Oliva F.H., Alarco-La Rosa L.F., Vega-Anticona A., Arbildo-Vega H.I. Biomechanics of anterior endocrowns with different designs and depths: Study of finite elements. J Clin Exp Dent. 2023; 15 (12): e1016-21. DOI: https://doi.org/10.4317/jced.60889

Sarkis-Onofre R., Amaral Pinheiro H., Poletto-Neto V., Bergoli C.D., Cenci M.S., Pereira-Cenci T. Randomized controlled trial comparing glass fiber posts and cast metal posts. Journal of Dentistry. 2020; 96: 103334. DOI: https://doi.org/10.1016/j.jdent.2020.103334

Lin J., Matinlinna J.P., Shinya A., Botelho M.G., Zheng Z. Effect of fiber post length and abutment height on fracture resistance of endodontically treated premolars prepared for zirconia crowns. Odontology. 2018; 106 (2): 215-22. DOI: https://doi.org/10.1007/s10266-017-0320-7

Palepwad A.B., Kulkarni R.S. In vitro fracture resistance of zirconia, glass-fiber, and cast metal posts with different lengths. J Indian Prosthodont Soc. 2020; 20 (2): 202-7. DOI: https://doi.org/10.4103/jips.jips_321_19

Tsintsadze N., Margvelashvili-Malament M., Natto Z.S., Ferrari M. Comparing survival rates of endodontically treated teeth restored either with glass-fiber-reinforced or metal posts: A systematic review and meta-analyses. J Prosthet Dent. 2022; S0022-3913 (22): 00047-6.

Alshabib A., Abid Althaqafi K., AlMoharib H.S., Mirah M., AlFawaz Y.F., Algamaiah H. Dental Fiber-Post Systems: An In-Depth Review of Their Evolution, Current Practice and Future Directions. Bioengineering (Basel). 2023;10 (5): 551. DOI: https://doi.org/10.3390/bioengineering10050551

Ulgey M., Zan R., Gorler O., Yesilyurt G., Cotur F. Evaluating Efficacy of Different Post Materials and Lengths on Bonding Strength Between Root Canal Dentin and Post Restorations: An Experimental Study. Nigerian Journal of Clinical Practice. 2020; 23 (7): 950. DOI: https://doi.org/10.4103/njcp.njcp_481_19

Hatta M., Shinya A., Vallittu P.K., Shinya A., Lassila L.V.J. High Volume Single Fiber Post Versus Low Volume Fiber Post: The Fracture Load of the Restored Tooth. Journal of Dentistry. 2011; 39 (1): 65-71. DOI: https://doi.org/10.1016/j.jdent.2010.10.004

Fantin L.L., Simões F., Alencar C. de M., Jordão-Basso K.C.F., Lima S.N.L., Bandéca M.C., et al. Bond strength and internal adaptation of customized glass fiber posts using different bulk-fill flow resins. J Clin Exp Dent. 2022; 14 (3): e263-8. DOI: https://doi.org/10.4317/jced.57683

Madfa A.A. Effect of Dental Glass Fiber Posts on Root Stresses and Fracture Behavior of Endodontically Treated Maxillary Central Incisors: A Finite Element Analysis Study. Cureus. 2023; 15 (8): e43056. DOI: https://doi.org/10.7759/cureus.43056

Martins M.D., Junqueira R.B., de Carvalho R.F., Lacerda M.F.L.S., Faé D.S., Lemos C.A.A. Is a fiber post better than a metal post for the restoration of endodontically treated teeth? A systematic review and meta-analysis. Journal of Dentistry. 2021; 112: 103750. DOI: https://doi.org/10.1016/j.jdent.2021.103750

Popescu A.D., Popa D.L., Nicola A.G., Dascălu I.T., Petcu C., Tircă T., et al. Post Placement and Restoration of Endodontically Treated Canines: A Finite Element Analysis Study. Int J Environ Res Public Health. 2022; 19 (15): 8928. DOI: https://doi.org/10.3390/ijerph19158928

Baraban D.J. Immediate restoration of pulpless teeth. The Journal of Prosthetic Dentistry. 1972; 28 (6): 607-12. DOI: https://doi.org/10.1016/0022-3913(72)90109-6

Willems G., Lambrechts P., Braem M., Celis J.P., Vanherle G. A classification of dental composites according to their morphological and mechanical characteristics. Dental Materials. 1992; 8 (5): 310-9. DOI: https://doi.org/10.1016/0109-5641(92)90106-M

Holmes D.C., Diaz-Arnold A.M., Leary J.M. Influence of post dimension on stress distribution in dentin. J Prosthet Dent. 1996; 75 (2): 140-7. DOI: https://doi.org/10.1016/S0022-3913(96)90090-6

Silva N.R., Castro C.G., Santos-Filho P.C.F., Silva G.R., Campos R.E., Soares P.V., et al. Influence of different post design and composition on stress distribution in maxillary central incisor: Finite element analysis. Indian J Dent Res. 2009; 20 (2): 153-8. DOI: https://doi.org/10.4103/0970-9290.52888

Corrêa G., Brondani L.P., Wandscher V.F., Pereira G.K.R., Valandro L.F., Bergoli C.D. Influence of remaining coronal thickness and height on biomechanical behavior of endodontically treated teeth: survival rates, load to fracture and finite element analysis. J Appl Oral Sci. 2018; 26: e20170313. DOI: https://doi.org/10.1590/1678-7757-2017-0313

Marinescu A.G., Abuabboud O., Zimbru Ștefana D., Cîrligeriu L.E., Piț B.A., Borcean I.A., et al. Influence of the Fiber Post Length on the Fracture Strength of Endodontically Treated Teeth. Medicina. 2023; 59 (10): 1797. DOI: https://doi.org/10.3390/medicina59101797

Özarslan M., Büyükkaplan U.Ş., Özarslan M.M. Comparison of the fracture strength of endodontically treated teeth restored with polyether ether ketone, zirconia and glass-fibre post-core systems. Int J Clin Pract. 2021; 75 (9): e14440. DOI: https://doi.org/10.1111/ijcp.14440

Junqueira R.B., de Carvalho R.F., Marinho C.C., Valera M.C., Carvalho C. A. T. Influence of glass fibre post length and remaining dentine thickness on the fracture resistance of root filled teeth. Int Endod J. 2017; 50 (6): 569-77. DOI: https://doi.org/10.1111/iej.12653

Hassouneh L., Matoug-Elwerfelli M., Al-Omari T., Setzer F.C., Nagendrababu V. Assessment of biomechanical behavior of immature non-vital incisors with various treatment modalities by means of three-dimensional quasi-static finite element analysis. Sci Rep. 2023; 13: 17491. DOI: https://doi.org/10.1038/s41598-023-44609-2

Da Silva N.R., Aguiar G.C.R., Rodrigues M. de P., Bicalho A.A., Soares P.B.F., Veríssimo C., et al. Effect of Resin Cement Porosity on Retention of Glass-Fiber Posts to Root Dentin: An Experimental and Finite Element Analysis. Braz Dent J. 2015; 26 (6): 630-6. DOI: https://doi.org/10.1590/0103-6440201300589

Huang M., Wang B., Zhang K., Yan X., Chen Z., Zhang X. Comparative analysis of stress distribution in residual roots with different canal morphologies: evaluating CAD/CAM glass fiber and other post-core materials. BMC Oral Health. 2024; 24 (1): 337. DOI: https://doi.org/10.1186/s12903-024-04109-9

Badami V., Ketineni H., PB S., Akarapu S., Mittapalli S.P., Khan A. Comparative Evaluation of Different Post Materials on Stress Distribution in Endodontically Treated Teeth Using the Finite Element Analysis Method: A Systematic Review. Cureus. 2022; 14 (9): e29753. DOI: https://doi.org/10.7759/cureus.29753

Haralur S.B., Alamrey A.A., Alshehri S.A., Alzahrani D.S., Alfarsi M. Effect of different preparation designs and all ceramic materials on fracture strength of molar endocrowns. Journal of Applied Biomaterials & Functional Materials. 2020; 18: 2280800020947329. DOI: https://doi.org/10.1177/2280800020947329

Dejak B., Młotkowski A. Strength comparison of anterior teeth restored with ceramic endocrowns vs custom-made post and cores. J Prosthodont Res. 2018; 62 (2): 171-6. DOI: https://doi.org/10.1016/j.jpor.2017.08.005

Lima M.O., Ferretti M.A., Caldas R.A., Barão V.A.R., França F.M.G., Lima D.A.N.L., et al. Application of polyetheretherketone (PEEK) posts: evaluation of fracture resistance and stress distribution in the root: in vitro and finite element analyses. Braz Oral Res. 2023; 37: e047. DOI: https://doi.org/10.1590/1807-3107bor-2023.vol37.0047

Li X., Kang T., Zhan D., Xie J., Guo L. Biomechanical behavior of endocrowns vs fiber post-core-crown vs cast post-core-crown for the restoration of maxillary central incisors with 1 mm and 2 mm ferrule height: A 3D static linear finite element analysis. Medicine (Baltimore). 2020; 99 (43): e22648. DOI: https://doi.org/10.1097/MD.0000000000022648

Published

2026-04-27