Effects of Acidic Beverages on Color Stability of Bulk-Fill Composites with Different Viscosities
DOI:
https://doi.org/10.15517/ijds.2022.49149Keywords:
Composite resins; Color; Dental filling; Dental materials; Dentistry; Food coloring agents.Abstract
The aim of this in vitro study is to investigate the effects of acidic beverages on the discoloration of bulk-fill composites with different viscosities. 144 disc-shaped specimens (8mm diameter × 2mm thick) were prepared from four different composite resins including a nanohybrid (Filtek Ultimate), two packable bulk-fill (Filtek Bulk Fill, Tetric N Ceram Bulk Fill), and a flowable bulk-fill composite (Tetric N Flow Bulk Fill). The specimens of each group were divided into 3 subgroups and submerged in distilled water, orange juice and coke (n=12). Color difference (∆E) were measured using CIELab color space and a compact spectrophotometer (VITA Easyshade) at baseline and after 30 days of immersion. Data were analyzed using two-way ANOVA and Tukey's HSD post-hoc tests (P<0.05). Two-way ANOVA revealed that both material type and staining solution significantly influenced ∆E values (P<0.001). Immersion in orange juice resulted in greater and significant discoloration over time in comparison to distilled water and coke (P<0.05). Tetric N Ceram (∆E=7.0) and Tetric N Flow (∆E=7.7) bulk-fill restoratives showed highest color change values after 30 days of immersion in orange juice. This study suggests that a discoloration above the clinically acceptable threshold (∆E>2.7) was observed for all bulk-fill composites tested. It can be speculated that orange juice has a more negative effect on the color stability compared to coke. Additionally, flowable bulk-fill composite was more prone to discoloration than condensable bulk-fill composites.
Downloads
References
Lynch C.D., Opdam N.J., Hickel R., Brunton P.A., Gurgan S., Kakaboura A., Shearer A.C., Vanherle G., Wilson N.H. Guidance on posterior resin composites: Academy of Operative Dentistry-European Section. J Dent. 2014; 42 (4): 377-83. DOI: https://doi.org/10.1016/j.jdent.2014.01.009
Van Ende A., De Munck J., Lise D.P., Van Meerbeek B. Bulk-Fill Composites: A Review of the Current Literature. J Adhes Dent. 2017;19 (2): 95-109.
Jadhav S., Hegde V., Aher G., Fajandar N. Influence of light curing units on failure of directcomposite restorations. J Conserv Dent. 2011; 14 (3): 225-7. DOI: https://doi.org/10.4103/0972-0707.85793
Rees J.S., Jagger D.C., Williams D.R., Brown G., Duguid W. A reappraisal of the incremental packing technique for light cured composite resins. J Oral Rehabil. 2004; 31 (1): 81-4. DOI: https://doi.org/10.1046/j.0305-182X.2003.01073.x
Tjan A.H., Bergh B.H., Lidner C. Effect of various incremental techniques on the marginal adaptation of class II composite resin restorations. J Prosthet Dent. 1992; 67 (1): 62-6. DOI: https://doi.org/10.1016/0022-3913(92)90051-B
Pilo R., Oelgiesser D., Cardash H.S. A survey of output intensity and potential for depth of cure among light-curing units in clinical use. J Dent. 1999; 27 (3): 235-41. DOI: https://doi.org/10.1016/S0300-5712(98)00052-9
Bucuta S., Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Investig. 2014; 18 (8): 1991-2000. DOI: https://doi.org/10.1007/s00784-013-1177-y
Tarle Z., Attin T., Marovic D., Andermatt L., Ristic M., Tauböck T.T. Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites. Clin Oral Investig. 2015; 19 (4): 831-40. DOI: https://doi.org/10.1007/s00784-014-1302-6
Ibarra E.T., Lien W., Casey J., Dixon S.A., Vandewalle K.S. Physical properties of a new sonically placed composite resin restorative material. Gen Dent. 2015; 63 (3): 51-6.
Czasch P., Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig. 2013; 17 (1): 227-35. DOI: https://doi.org/10.1007/s00784-012-0702-8
Ilie N., Bucuta S., Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent. 2013; 38 (6): 618-25. DOI: https://doi.org/10.2341/12-395-L
Kim R.J., Kim Y.J., Choi N.S., Lee I.B. Polymerization shrinkage, modulus, and shrinkage stress related to tooth-restoration interfacial debonding in bulk-fill composites. J Dent. 2015; 43 (4): 430-9. DOI: https://doi.org/10.1016/j.jdent.2015.02.002
Berger S.B., Petri Z., Hass V., et al. Effect of whitening mouthrinses on bulk-fill composites. Am J Dent. 2019; 32 (5): 235-9.
Abdelraouf R.M., Habib N.A. Color-Matching and Blending-Effect of Universal Shade Bulk-Fill-Resin-Composite in Resin-Composite-Models and Natural Teeth. Biomed Res Int. 2016; 2016: 4183432. DOI: https://doi.org/10.1155/2016/4183432
Paravina R.D., Westland S., Kimura M., Powers J.M., Imai F.H. Color interaction of dental materials: blending effect of layered composites. Dent Mater. 2006; 22 (10): 903-8. DOI: https://doi.org/10.1016/j.dental.2005.11.018
Shamszadeh S., Sheikh-Al-Eslamian S.M., Hasani E., Abrandabadi A.N., Panahandeh N. Color stability of the bulk-fill composite resins with different thickness in response to coffee/water immersion. Int J Dent. 2016; 2016: 7186140. DOI: https://doi.org/10.1155/2016/7186140
Bayne S.C., Schmalz G. Reprinting the classic article on USPHS evaluation methods for measuring the clinical research performance of restorative materials. Clin Oral Investig. 2005; 9 (4): 209-14. DOI: https://doi.org/10.1007/s00784-005-0017-0
Jefferies S.R. Abrasive finishing and polishing in restorative dentistry: a state-of-the-art review. Dent Clin North Am. 2007; 51 (2): 379. DOI: https://doi.org/10.1016/j.cden.2006.12.002
Barakah H.M., Taher N.M. Effect of polishing systems on stain susceptibility and surface roughness of nanocomposite resin material. J Prosthet Dent. 2014; 112 (3): 625-31. DOI: https://doi.org/10.1016/j.prosdent.2013.12.007
Chen H., Huang J., Dong X., et al. A systematic review of visual and instrumental measurements for tooth shade matching. Quintessence Int. 2012; 43 (8): 649-59.
Şişmanoğlu S., Gürcan A.T. Evaluation of stain susceptibility of different CAD/CAM blocks after immersion in coffee. J DU Health Sci Inst. 2021; 11 (3): 284-9. DOI: https://doi.org/10.33631/duzcesbed.840660
Tekçe N., Tuncer S., Demirci M., Serim M.E., Baydemir C. The effect of different drinks on the color stability of different restorative materials after one month. Restor Dent Endod. 2015; 40 (4): 255-61. DOI: https://doi.org/10.5395/rde.2015.40.4.255
Chu S.J., Trushkowsky R.D., Paravina R.D. Dental color matching instruments and systems. Review of clinical and research aspects. J Dent. 2010; 38 (Suppl 2): e2-e16. DOI: https://doi.org/10.1016/j.jdent.2010.07.001
Joiner A. Tooth colour: a review of the literature. J Dent. 2004; 32 (Suppl 1): 3-12. DOI: https://doi.org/10.1016/j.jdent.2003.10.013
Joiner A., Luo W. Tooth colour and whiteness: A review. J Dent. 2017; 67 (S): S3-S10. DOI: https://doi.org/10.1016/j.jdent.2017.09.006
Tanthanuch S., Kukiattrakoon B., Eiam-O-Pas K., et al. Surface changes of various bulk-fill resin-based composites after exposure to different food-simulating liquid and beverages. J Esthet Restor Dent. 2018; 30 (2): 126-35. DOI: https://doi.org/10.1111/jerd.12349
Kim-Pusateri S., Brewer J.D., Davis E.L., Wee A.G. Reliability and accuracy of four dental shade-matching devices. J Prosthet Dent. 2009; 101 (3): 193-9. DOI: https://doi.org/10.1016/S0022-3913(09)60028-7
Paravina R.D., Ghinea R., Herrera L.J., et al. Color difference thresholds in dentistry. J Esthet Restor Dent. 2015; 27 (Suppl 1): S1-S9. DOI: https://doi.org/10.1111/jerd.12149
Dietschi D., Campanile G., Holz J., Meyer J.M. Comparison of the color stability of ten new-generation composites: an in vitro study. Dent Mater. 1994; 10 (6): 353-62. DOI: https://doi.org/10.1016/0109-5641(94)90059-0
Erdilek D., Sismanoglu S., Gumustas B., Efes B.G. Effects of ultrasonic and sonic scaling on surfaces of tooth-colored restorative materials: An in vitro study. Niger J Clin Pract. 2015; 18 (4): 467-71. DOI: https://doi.org/10.4103/1119-3077.151776
Guler A.U., Yilmaz F., Kulunk T., Guler E., Kurt S. Effects of different drinks on stainability of resin composite provisional restorative materials. J Prosthet Dent. 2005; 94 (2): 118-24. DOI: https://doi.org/10.1016/j.prosdent.2005.05.004
Tunc E.S., Bayrak S., Guler A.U., Tuloglu N. The effects of children's drinks on the color stability of various restorative materials. J Clin Pediatr Dent. 2009; 34 (2): 147-50. DOI: https://doi.org/10.17796/jcpd.34.2.953q255621436788
Briso A.L., Caruzo L.P., Guedes A.P., Catelan A., dos Santos P.H. In vitro evaluation of surface roughness and microhardness of restorative materials submitted to erosive challenges. Oper Dent. 2011; 36 (4): 397-402. DOI: https://doi.org/10.2341/10-356-L
Arregui M., Giner L., Ferrari M., Vallés M., Mercadé M. Six-month color change and water sorption of 9 new-generation flowable composites in 6 staining solutions. Braz Oral Res. 2016; 30 (1): e123. DOI: https://doi.org/10.1590/1807-3107bor-2016.vol30.0123
Ozera E.H., Pascon F.M., Correr A.B., et al. Color Stability and Gloss of Esthetic Restorative Materials after Chemical Challenges. Braz Dent J. 2019; 30 (1): 52-7. DOI: https://doi.org/10.1590/0103-6440201902263
Catelan A., Briso A.L., Sundfeld R.H., Goiato M.C., dos Santos P.H. Color stability of sealed composite resin restorative materials after ultraviolet artificial aging and immersion in staining solutions. J Prosthet Dent. 2011;105 (4): 236-41. DOI: https://doi.org/10.1016/S0022-3913(11)60038-3
Lauvahutanon S., Shiozawa M., Takahashi H., et al. Discoloration of various CAD/CAM blocks after immersion in coffee. Restor Dent Endod. 2017; 42 (1): 9-18. DOI: https://doi.org/10.5395/rde.2017.42.1.9
Liberman R., Combe E.C., Piddock V., Pawson C., Watts D.C. Development and assessment of an objective method of colour change measurement for acrylic denture base resins. J Oral Rehabil. 1995; 22 (6): 445-9. DOI: https://doi.org/10.1111/j.1365-2842.1995.tb00799.x
Tan B.L., Yap A.U., Ma H.N., Chew J., Tan WJ. Effect of beverages on color and translucency of new tooth-colored restoratives. Oper Dent. 2015; 40 (2): E56-E65. DOI: https://doi.org/10.2341/149027-L
Theobald A.H., Wong B.K., Quick A.N., Thomson W.M. The impact of the popular media on cosmetic dentistry. N. Z. Dent J. 2006; 102 (3): 58-63.
Sengez G., Dörter C. Estetik diş hekimliğinde renk seçimi. Selcuk Dent J. 2019; 6 (2): 213-20. DOI: https://doi.org/10.15311/selcukdentj.430209
Nasim I., Neelakantan P., Sujeer R., Subbarao C.V. Color stability of microfilled, microhybrid and nanocomposite resins--an in vitro study. J Dent. 2010; 38 (Suppl 2): e137-e42. DOI: https://doi.org/10.1016/j.jdent.2010.05.020
Published
Issue
Section
License
Copyright (c) 2022 CC-BY-NC-SA 4.0

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
ODOVTOS - Int. J. Dent. Sc. endorses CC BY-NC-SA
This license enables reusers to distribute, remix, adapt, and build upon the material in any medium or format for noncommercial purposes only, and only so long as attribution is given to the creator. If you remix, adapt, or build upon the material, you must license the modified material under identical terms. CC BY-NC-SA includes the following elements:
BY: credit must be given to the creator.
NC: Only noncommercial uses of the work are permitted.
SA: Adaptations must be shared under the same terms.





