Análisis morfométrico del surco, canal y foramen infraorbitario en tomografías computarizadas de una población iraní

Autores/as

  • Mojtaba Vaezi Student Research Committee, Qazvin University of Medical Sciences, Qazvin, Iran. Autor/a
  • Aida Karagah Assistant Professor, Department of Oral and Maxillofacial Surgery, Qazvin University of Medical Sciences, Qazvin, Iran. Assistant Professor, Medical Microbiology Research Center, Qazvin University of Medical Sciences, Qazvin, Iran. Autor/a https://orcid.org/0000-0003-3673-3671
  • Farnaz Taghavi-Damghani Assistant Professor, Department of Prosthodontics, School of dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran. Autor/a https://orcid.org/0000-0002-1632-2616
  • Maryam Tofangchiha Professor, Department of Oral and Maxillofacial radiology, Qazvin University of Medical Sciences, Qazvin, Iran. Autor/a https://orcid.org/0000-0002-5515-2189
  • Ahad Alizadeh Assistant Professor, Medical Microbiology Research Center, Qazvin University of Medical Sciences, Qazvin, Iran. Autor/a https://orcid.org/0000-0002-0385-463X
  • Rodolfo Reda Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy. Autor/a https://orcid.org/0000-0003-1532-6524
  • Luca Testarelli epartment of Oral and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy. Autor/a https://orcid.org/0000-0003-3904-3000

DOI:

https://doi.org/10.15517/ijds.2025.63567

Palabras clave:

Tomografía computarizada; Surco infraorbitario; Canal infraorbitario; Foramen infraorbitario.

Resumen

Este estudio evaluó morfométricamente el surco infraorbitario (IOG), el canal (IOC) y el foramen (IOF) en tomografías computarizadas (TC) de una población iraní. Este estudio transversal evaluó las tomografías computarizadas de 126 pacientes que se presentaron en un hospital en la ciudad de Qazvin, Irán, durante 2020-2022, que fueron seleccionados por muestreo de conveniencia. Un cirujano oral y maxilofacial y un radiólogo oral y maxilofacial identificaron los puntos de referencia anatómicos relevantes y las mediciones fueron realizadas por un estudiante de odontología capacitado. Los datos se analizaron mediante una prueba t independiente y una prueba de correlación de Pearson (alfa=0,05). La longitud media del IOF fue de 9,86±1,34 mm, la longitud media del IOG fue de 12,78±1,57 mm, el ángulo medio del IOF-IOG fue de 136,78±6,90 grados, el ángulo medio del plano vertical del IOF fue de 26,92±5,74 grados, el ángulo medio del plano horizontal del IOF fue de 58,54±6,18 grados, la distancia horizontal media entre el IOF y el plano sagital que pasa por la escotadura supraorbitaria (SON) fue de 4,85±0,98 mm, la distancia horizontal media entre el IOF y el plano sagital que pasa por la línea media fue de 23,04±2,90 mm, la distancia vertical media entre el IOF y el reborde infraorbitario (IOR) fue de 9,22±1,45 mm, la distancia media entre el IOF y la espina nasal anterior (ANS) fue de 27,63±10,99 mm, el ángulo medio entre el IOF y el ANS fue de 33,52±5,46 grados y el grosor medio del tejido blando sobre el IOF fue de 10,60±2,04 mm. No se encontraron diferencias significativas en los parámetros en función de la edad (P>0,05). Las distancias IOF-línea media y IOF-IOR fueron significativamente mayores en hombres que en mujeres (P<0,05). No se encontraron otras diferencias significativas en función del género (P>0,05). Según los resultados, las distancias IOF-línea media y IOF-IOR fueron significativamente mayores en hombres iraníes que en mujeres. Los resultados obtenidos con respecto a la posición de IOC, IOF e IOG en las tomografías computarizadas de la población de estudio iraní pueden ayudar a maximizar el éxito de los procedimientos clínicos relacionados.

Descargas

Los datos de descarga aún no están disponibles.

Referencias

Orhan K., Misirli M., Aksoy S., Seki U., Hincal E., Ormeci T., et al. Morphometric analysis of the infraorbital foramen, canal and groove using cone beam CT: considerations for creating artificial organs. Int J Artif Organs. 2016; 39 (1): 28-36. DOI: https://doi.org/10.5301/ijao.5000469

Hwang S.H., Kim S.W., Park C.S., Kim S.W., Cho J.H., Kang J.M. Morphometric analysis of the infraorbital groove, canal, and foramen on three-dimensional reconstruction of computed tomography scans. Surg Radiol Anat. 2013; 35 (7): 565-71. DOI: https://doi.org/10.1007/s00276-013-1077-5

Singh R. Morphometric analysis of infraorbital foramen in Indian dry skulls. Anat Cell Biol. 2011; 44 (1): 79-83. DOI: https://doi.org/10.5115/acb.2011.44.1.79

Bahsi I., Orhan M., Kervancioglu P., Yalcin E.D. Morphometric evaluation and surgical implications of the infraorbital groove, canal and foramen on cone-beam computed tomography and a review of literature. Folia Morphol (Warsz). 2019; 78 (2): 331-43. DOI: https://doi.org/10.5603/FM.a2018.0084

Lee T., Lee H., Baek S. A three-dimensional computed tomographic measurement of the location of infraorbital foramen in East Asians. Journal of Craniofacial Surgery. 2012; 23 (4): 1169-73. DOI: https://doi.org/10.1097/SCS.0b013e31824f658a

Nanayakkara D., Peiris R., Mannapperuma N., Vadysinghe A. Morphometric Analysis of the Infraorbital Foramen: The Clinical Relevance. Anat Res Int. 2016; 2016: 7917343. DOI: https://doi.org/10.1155/2016/7917343

Kazkayasi M., Ergin A., Ersoy M., Bengi O., Tekdemir I., Elhan A. Certain anatomical relations and the precise morphometry of the infraorbital foramen-canal and groove: an anatomical and cephalometric study. The Laryngoscope. 2001; 111 (4): 609-14. DOI: https://doi.org/10.1097/00005537-200104000-00010

Rahman M., Richter E.O., Osawa S., Rhoton A.L. Jr. Anatomic study of the infraorbital foramen for radiofrequency neurotomy of the infraorbital nerve. Neurosurgery. 2009; 64 (5 Suppl 2): 423-7; discussion 427-8. DOI: https://doi.org/10.1227/01.NEU.0000336327.10368.79

Chung M.S., Kim H.J., Kang H.S., Chung I.H. Locational Relationship of the Supraorbital Notch or Foramen and Infraorbital and Mental Foramina in Koreans. Acta Anatomica. 2008; 154 (2): 162-6. DOI: https://doi.org/10.1159/000147763

Chrcanovic B.R., Abreu M.H.N.G., Custódio A.L.N. A morphometric analysis of supraorbital and infraorbital foramina relative to surgical landmarks. Surgical and radiologic anatomy. 2011; 33: 329-35. DOI: https://doi.org/10.1007/s00276-010-0698-1

Dagistan S., Miloglu O., Altun O., Umar E.K. Retrospective morphometric analysis of the infraorbital foramen with cone beam computed tomography. Niger J Clin Pract. 2017; 20 (9): 1053-64. DOI: https://doi.org/10.4103/1119-3077.217247

Suresh S., Voronov P., Curran J. Infraorbital nerve block in children: a computerized tomographic measurement of the location of the infraorbital foramen. Regional anesthesia and pain medicine. 2006; 31 (3): 211-4. DOI: https://doi.org/10.1016/j.rapm.2005.11.017

Schumacher G.H. Principles of skeletal growth. Fundamentals of craniofacial growth. CRC Press; 2017 (pp. 1-22). DOI: https://doi.org/10.1201/9780203755327-1

Publicado

2025-04-30