Abstract
The aim of this study was to compare the shear bonding strength between new brackets, recycled brackets by the Ortho-Cycle Co. and sandblasted brackets along with a sterilization process after being debonded. Thus, 60 human bicuspids extracted for orthodontics purposes were divided into 3 groups to bond the brackets. Group 1: new brackets. Group 2: these brackets were removed from Group 1, they were sandblasted and placed in the ultrasound and sterilized. Group 3: these brackets were recycled by the Ortho-Cycle Co. The brackets were debonded using the Instron Universal Test machine and the results were recorded. Then the brackets were inspected using an optical microscope and a scanning electron microscope to perform the Adhesive Remnant Index. The group of recycled brackets had the highest mean value of 7.55 MPa, then, the new brackets group with a mean value of 7.24 MPa. And finally the minor value was for the sandblasted brackets with a mean value of 6.43 MPa. The results of this study shows that the three groups of brackets studied had not statistical significant differences in their mean values in their resistance to debonding and that the three groups of brackets fulfill the requirements to be bonded to the teeth.
References
Artun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid – etch pretreatment. Am J Orthod Dentofacial Orthop 1984;85:333-40.
Sunna S, Rock WP. Effect of sandblasting on the retention of orthodontic brackets: a controlled clinical trial. J Orthod 2008;35:43-48.
Reynolds IR, Von Fraunhofer JA. A review of direct orthodontic bonding. Brit J Orthod 1975;2:143-6.
Maccoll GA, Rossouw PE, Titley KC, Yamin C. The relationship between bond strength and base surface area using conventional and micro-etched foil-mesh bases. Am J Orthod Dentofacial Orthop 1996;109:338-339.
Quick AN, Harris M, Joseph VP. Office reconditioning of stainless steel orthodontic attachments. Eur J Orthod 2005;27:231–236.
Jacobson A. The effects of in-office reconditioning on the morphology of slots and bases of stainless steel brackets and on the shear/peel bond strength. Am J Orthod Dentofacial Orthop 2002;121:433.
Regan D, Van Noort R, O'Keefe C. The effects of recycling on the tensile bond strength of new and clinically used stainless steel orthodontic brackets: an in vivo study. Br J Orthod 1990;17(2):137-45.
Sonis AL. Air abrasion of failed bonded metal brackets: A study of shear bond strength and surface characteristics as determined by scanning electron microscopy. Am J Orthod Dentofac Orthop 1996;110:96-8.
Luque HJ, Pérez LF, Carhuamaca GJ, Coronado MA. Fuerza de adhesión de brackets reacondicionados con diferentes técnicas adheridos repetidas veces en la misma superficie del esmalte. Odontol. Sanmarquina 2008;11(2):60-65.
Buchman DJ. Effects of recycling on metallic direct-bond orthodontic brackets. Am J Orthod 1980;77:654-668.
Matasa CG. Orthodontic recycling at the crossroads. J. Clin. Orthod. 2003;37:133-139.
Comunicación personal con la empresa Ortho-Cycle Co., marzo del 2011.
Harini T, Reddy S. Effect of an adhesion booster on the bond strength of new and recycled brackets. Annals and Essences of Dentistry 2011;3:20-22.
Matasa CG. Metal strength of direct bonding brackets. Am J Orthod Dentofacial Orthop 1998;113:282-6.
Fox NA, McCabe JF, Buckley JG. A critic of bond strength testing in orthodontics. Br J Orthod. 1994;21(1):33-43.
Martínez K. Resistencia al desprendimiento de brackets cementados con el sistema de autograbado a diferentes tiempos desde su activación: estudio “in vitro” (Tesis). Universidad Intercontinental, 2012.
Bishara SE, Ajlouni R, Laffoon JF. Effect of thermocycling on the shear bond strength of a cyanoacrylate orthodontic adhesive. Am J Orthod Dentofacial Orthop 2003; 123:21-4.
Mascia VE, Chen SR. Shearing strengths of recycled direct bonding brackets. Am J Orthod 1982;82:211-216.